- 30 -
WALL MOUNTED
ASTG30, 34KMTA
11. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE: Incorrect settings can cause a product malfunction.
11-1. Function settings on indoor unit
Depending on the connected remote controller type, following setting is required:
Component location
Component on the indoor unit main PC board used for this setting is located as shown in the
following figure.
Connected remote controller DIP switch Jumper (JM9)
2-wire-type wired remote controller is connected
3-wire-type wired remote controller is connected
(Factory setting)
2WIRE/3WIRE
JM9
(Disconnected)
(Connected)
(Factory setting)
JM9
Indoor unit main PC board
JM9
2WIRE/3WIRE
2WIRE/3WIRE