EasyManua.ls Logo

Fujitsu ASTG30KMTA - Model: AOTG34 KMTA

Fujitsu ASTG30KMTA
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 43 -
OUTDOOR UNIT
AOTG30, 34KMTA
1-2. Model: AOTG34KMTA
Type Inverter heat pump
Model name
AOTG34KMTA
Power supply 240 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 12.9
Fan
Airflow rate
Cooling
l/s (m
3
/h)
1,139 (4,100)
Heating 1,139 (4,100)
Type × Q'ty Propeller fan × 1
Motor output W 111
Sound pressure level *1
Cooling
dB(A)
50
Heating 54
Sound power level dB(A) 67
Heat exchanger type
Dimensions (H × W × D)
mm
Main: 882 × 957 × 18.19 & 882 × 927 × 18.19
Sub: 882 × 580 × 18.19
Fin pitch 1.45
Rows × Stages Main: 2 × 42, Sub: 1 × 42
Pipe type Copper
Fin
Type (Material) Corrugate (Aluminum)
Surface
treatment
Corrosion resistance (Blue fin)
Compressor
Type × Q'ty Hermetic motor compressor × 1
Motor output W 2,200
Refrigerant
Type R32
Charge g 2,000
Refrigerant oil
Type RmM68AF
Amount
cm
3
800
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
914 × 970 × 370
Gross 1,048 × 1,064 × 479
Weight
Net
kg
75
Gross 82
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Flare
Pre-charge length
m
30
Max. length 50
Max. height difference 30
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material LDPE
Size mm Ø 13.0 (I. D.), Ø 16.0 to Ø 16.7 (O. D.)
International protection rating IPX4
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 7.5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.