- 43 -
OUTDOOR UNIT
AOTG30, 34KMTA
1-2. Model: AOTG34KMTA
Type Inverter heat pump
Model name
AOTG34KMTA
Power supply 240 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 12.9
Fan
Airflow rate
Cooling
l/s (m
3
/h)
1,139 (4,100)
Heating 1,139 (4,100)
Type × Q'ty Propeller fan × 1
Motor output W 111
Sound pressure level *1
Cooling
dB(A)
50
Heating 54
Sound power level dB(A) 67
Heat exchanger type
Dimensions (H × W × D)
mm
Main: 882 × 957 × 18.19 & 882 × 927 × 18.19
Sub: 882 × 580 × 18.19
Fin pitch 1.45
Rows × Stages Main: 2 × 42, Sub: 1 × 42
Pipe type Copper
Fin
Type (Material) Corrugate (Aluminum)
Surface
treatment
Corrosion resistance (Blue fin)
Compressor
Type × Q'ty Hermetic motor compressor × 1
Motor output W 2,200
Refrigerant
Type R32
Charge g 2,000
Refrigerant oil
Type RmM68AF
Amount
cm
3
800
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
914 × 970 × 370
Gross 1,048 × 1,064 × 479
Weight
Net
kg
75
Gross 82
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Flare
Pre-charge length
m
30
Max. length 50
Max. height difference 30
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material LDPE
Size mm Ø 13.0 (I. D.), Ø 16.0 to Ø 16.7 (O. D.)
International protection rating IPX4
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.