- 42 -
OUTDOOR UNIT
AOTG30, 34KMTA
1. Specifications
1-1. Model: AOTG30KMTA
Type Inverter heat pump
Model name
AOTG30KMTA
Power supply 240 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 10.4
Fan
Airflow rate
Cooling
l/s (m
3
/h)
861 (3,100)
Heating 945 (3,400)
Type × Q'ty Propeller fan × 1
Motor output W 100
Sound pressure level *1
Cooling
dB(A)
50
Heating 54
Sound power level dB(A) 67
Heat exchanger type
Dimensions
(H × W × D)
mm
798 × 900 × 36.4
Fin pitch 1.30
Rows × Stages 2 × 38
Pipe type Copper
Fin type
Type (Material) Corrugate (Aluminum)
Surface treatment Corrosion resistance (Blue fin)
Compressor
Type × Q'ty Hermetic motor compressor × 1
Motor output W 2,200
Refrigerant
Type R32
Charge g 1,650
Refrigerant oil
Type RmM68AF
Amount
cm
3
800
Enclosure
Material Steel sheet
Color
Beige
Approximate color of MUNSELL 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
830 × 900 × 330
Gross 970 × 1,050 × 445
Weight
Net
kg
61
Gross 67
Connection pipe
Size
Liquid
mm
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Flare
Pre-charge length
m
20
Max. length 50
Max. height difference 30
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material LDPE
Size mm Ø 13.0 (I. D.), Ø 16.0 to Ø 16.7 (O. D.)
International protection rating IPX4
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.