2. MODEL SELECTION
FLOOR TYPE6-2-5.
MODEL : AG
 
G09LVCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0  -16.0 2.36 2.18 2.00 1.83 1.59 
-10.0  -11.0  2.64 2.44 2.24 2.05 1.78 
-5.0  -7.0  2.94 2.71 2.49 2.28 1.98 
0.0  -2.0  3.21 2.96 2.72  2.49 2.17 
5.0  3.0  3.44  3.18  2.92 2.67 2.32 
7.0  6.0  3.52 3.25 2.99 2.73  2.38 
10.0  8.0  3.52 3.25 2.99 2.73  2.38 
15.0  10.0  3.52 3.25 2.99 2.73  2.38 
20.0  15.0  3.52 3.25 2.99 2.73  2.38 
MODEL : AG
 
G12LVCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0  -16.0 3 .13  2.88 2.65 2.42 2.11 
-10.0  -11.0  3.50 3.23 2.97 2.71 2.36 
-5.0  -7.0  3.89 3.59 3.30 3.02 2.63 
0.0  -2.0  4.25 3.92 3.61 3.29 2.87 
5.0  3.0  4.56  4.21  3.87 3.53 3.08 
7.0  6.0  4.66 4.30 3.96 3.62 3.15 
10.0  8.0  4.66 4.30 3.96 3.62 3.15 
15.0  10.0  4.66 4.30 3.96 3.62  3.15 
20.0  15.0  4.66 4.30 3.96 3.62 3.15 
MODEL : AG
 
G14LVCA
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0  -16.0 3.79  3.50 3.22 2.94 2.56 
-10.0  -11.0  4.24 3.91 3.60 3.29 2.86 
-5.0  -7.0  4.72 4.35 4.00 3.65 3.18 
0.0  -2.0  5.15  4.75 4.37 3.99 3.48 
5.0  3.0  5.52 5.10 4.69 4.28 3.73 
7.0  6.0  5.65 5.22 4.80 4.38 3.82 
10.0  8.0  5.65 5.22 4.80 4.38 3.82 
15.0  10.0  5.65 5.22 4.80 4.38 3.82 
20.0  15.0  5.65 5.22 4.80 4.38 3.82 
HEATING CAPACITY 
TC : Total Capacity kW.
The data is based on the following conditions.  
Pipe length : 5m [Outdoor unit - Branch box],  3m [Branch box - Indoor unit]  
Height difference : 0m [Outdoor unit - Indoor unit].
- (02 - 37) -
MODEL
SELECTION
MODEL
SELECTION