02 - 17
)
-
OUTDOOR UNIT
AO
G12-24LAL
OUTDOOR UNIT
AO
G12-24LAL
SAFETY DEVICES10.
Protection form
Model
AO
G12LALL AO
G14LALL AO
G18LALL AO
G24LALA
Circuit protection
Current fuse
(Near the terminal)
250V 20A
250V 5A
Current fuse
(Main printed
circuit board)
250V 15A
250V 3.15A
Fan motor
protection
Thermal protection
program
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
OFF : 110
+15
-10
°C
ON : 105
+15
-10
°C
Compressor
protection
Terminal protection program
(Compressor temp.)
OFF : 110°C
ON : After 40 minutes and 80°C or less
Thermal protection program
(Discharge temp.)
OFF : 110°C
ON : After 7 minutes