Model: AOUH24LUAS1
Fan speed is defined by outdoor temperature and compressor frequency.
Unit: rpm
Fan step Cooling or dry Heating
13 830
12 830
11 740
10 700 830
9 650 740
8 570 690
7 570 620
6 540 590
5 510 480
4 480 410
3 480 340
2 400 270
1 200 200
S-HIGH 830
→hen the compressor frequency increases, the outdoor fan speed also changes to the higher
speed.
→hen the compressor frequency decreases, the outdoor fan speed also changes to the lower
speed.
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 830 rpm