4. Connection and Settings
Connecting Cascade Cables
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Copyright 2019 FUJITSU LIMITED P3AM-8012-14ENZ0
52
■ Procedure for cascade cable connection
The procedure for connecting a cascade cable is described below.
1 Connect the cascade cable to power synchronized unit#0.
Connect the cascade cable connector to the CASCADE port.
2 Check that power synchronized unit#1 is turned on.
Check that the CHECK LED is off and the POWER LED is blinking green on the power synchronized unit.
3 Connect the connector at the other end to power synchronized unit#1.
Connect the connector at the other end of the cascade cable to the AC SENSOR port.
End of procedure
When connecting the cascade cable, check the direction of the connector tab and firmly insert it all the way in.
When disconnecting a cascade cable, hold the tab of the connector while pulling it out.
Power synchronized unit#0
CASCADE port
Cascade cable
Power synchronized unit#1
Cascade cable
AC SENSOR port