Chapter 1 Overview
1.2 References for Setup
FUJITSU Storage ETERNUS LT20 S2/LT40 S2/LT60 S2 Tape Library User’s Guide -Server Connection-
Copyright 2021 FUJITSU LIMITED P3AM-5322-12ENZ0
21
1.2.1.3 Fibre Channel Connection (Fabric Connection) for Solaris OS
The following procedure explains how to connect the LT20 S2/LT40 S2/LT60 S2 to a Solaris OS server with a
fabric connection.
Workflow
Making a Check before Starting the Procedure
Check the environment (operating system, backup software, and HBAs) of the server to be
connected to the LT20 S2/LT40 S2/LT60 S2.
- "1.1 Operating Environment" (page 17)
Setting the LT20 S2/LT40 S2/LT60 S2
Perform the settings for the LT20 S2/LT40 S2/LT60 S2.
IMPORTANT
Change the topology setting to "Point to Point". Set a fixed value for the link speed.
- "Chapter 2 Setting the LT20 S2/LT40 S2/LT60 S2" (page 31)
- "2.2 Settings for Fibre Channel Connections" (page 31)
- "2.2.1 Setting the Link Speed" (page 31)
- "2.2.3 Setting the Topology (for Connections via FC Switches)" (page 33)
Setting the Operating System
Perform the settings for the HBA driver and the device driver.
- "3.1 Solaris OS" (page 35)
- "3.1.2 Fibre Channel Connections" (page 36)