EasyManua.ls Logo

Fujitsu Inverter - Page 5

Fujitsu Inverter
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
En-4
Fig. 5 Remote Controller
H
Signal Transmitter
I
MODE button
J
10°C HEAT button
K
ECONOMY button
L
SLEEP button
M
TIMER MODE button
N
FAN button
O
START/STOP button
P
SET TEMP. button (
/
)
Q
SET button
R
SWING button
S
TIMER SET (
/ ) button
T
CLOCK ADJUST button
U
TEST RUN button
This button is used when installing the
conditioner, and should not be used under
normal conditions, as it will cause the air
conditioners thermostat function to operate
incorrectly.
If this button is pressed during normal op-
eration, the unit will switch to test operation
mode, and the Indoor Unit’s OPERATION
Indicator Lamp and TIMER Indicator Lamp
will begin to ash simultaneously.
To stop the test operation mode, press the
START/STOP button to stop the air condi-
tioner.
V
RESET button
W
Remote Controller Display (Fig. 6)
X
Temperature SET Display
Y
Operating Mode Display
Z
SLEEP Display
[
Transmit Indicator
\
Fan Speed Display
]
SWING Display
`
Timer Mode Display
a
Clock Display
Fig. 1 Indoor Unit
1
Operating Control Panel (Fig. 2)
2
Air Outlet Selection switch
3
MANUAL AUTO button
When the MANUAL AUTO button is pressed
in for more than 10 seconds, the forced
cooling operation will start.
The forced cooling operation is used at the
time of installation.
Only for authorized service personnel's use.
When the forced cooling operation starts by
any chance, press the START/STOP button
to stop the operation.
4
Indicator (Fig. 3)
5
Remote Control Signal Receiver
6
OPERATION Indicator Lamp (green)
7
TIMER Indicator Lamp (orange)
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a fault
has occurred with the timer setting (See
Page 16 Auto Restart).
8
ECONOMY Indicator Lamp (green)
9
Intake Grille (Fig. 4)
0
Front Panel
A
Air Filter
B
Air ow Direction Louver
C
Damper
D
Right-Left Louver
(behind Airflow Direction Louver and
Damper)
E
Drain Hose
F
Air Cleaning Filter
G
Rope
9378532038-03_OM.indb 49378532038-03_OM.indb 4 2/25/2013 3:46:30 PM2/25/2013 3:46:30 PM

Other manuals for Fujitsu Inverter