68 Operating Manual RX200 S7
Starting up and operation
Indicator on hot-plug power supply unit
Figure 10: Indicator on hot-plug power supply unit
1 Indicator on hot-plug power supply unit (two colors)
800 W power supply unit:
Flashes green when the server is switched off, but mains voltage is
present (standby mode).
Lights up green when the server is switched on and functioning properly.
Flashes orange when a predictable error has been detected, but the
power supply unit is still running.
Lights up orange in case of OCP/OVP or when the fan of the power
supply unit has failed.
450 W power supply unit:
Flashes green when the server is switched off, but mains voltage is
present (standby mode).
Lights up green when the server is switched on and functioning properly.
Flashes orange when a predictable error has been detected, but the
power supply unit is still running.
Lights up orange in case of OCP/OVP or when the fan of the power
supply unit has failed.