8.6 Incorrect date and time
Ê Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY RX2540 M1 Upgrade and Maintenance
Manual") or contact our customer service team.
8.7 System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê Check the settings for the hard disk drives (SAS Device Configuration) and the
additional settings in the SAS configuration menu.
8.8 Hard disk drive error messages at system
boot
Various hard disk drive error messages may occur when the system is
rebooted. These error messages are caused by modifications in the selected
RAID configuration.
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller
configuration program.