Switching the server on and off Switching the SE700 / SE500 on and off
U41858-J-Z126-2-76 75
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. April 2017 Stand 15:41.41 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303913_BA_Basis_update_2\prod_e\ba_basis.k08
8.2 Switching the SE700 / SE500 on and off
Normally the Management Unit, Server Unit and Application Unit are switched on and off
via remote administration PCs, see the information in the “Quick Guide” [7].
This chapter describes the actions for switching these units on/off which can be performed
directly on the SE server SE700 or SE500 as an alternative to switching it on/off remotely.
Further information on on this subject and also on the subjects IPL, console and SE
Manager is provided in the “Operation and Administration” manual [5].
8.2.1 Switching off in an emergency
The SE700 and SE500 comply with the relevant safety regulations for IT equipment,
including electrical office equipment.
In an emergency the devices must immediately be switched off (e.g. when the housing or
power cable is damaged or liquid or foreign material gets into the equipment).
This can be done by pressing the POWER STAND-BY button on the server's control panel
or by pressing the UNIT EMERGENCY switch. Pressing the UNIT EMERGENCY switch
causes an abbreviated power-off routine to be started.
The UNIT EMERGENCY switch is at the bottom of the control panel (see figure 31 on
page 76).
Pressing the POWER STAND-BY button or UNIT EMERGENCY switch does not
disconnect the system completely from the power source (POWER STAND-BY). To
cut the entire system off from the power source, you must switch off/remove the
fuses from the customer's in-house installation.
Please then notify Customer Support.