7. PRESSURE SENSOR, SOLENOID COIL removal
7-1. PRESSURE SENSOR removal
Pressure Sensor
(Low Pressure)
Pressure Switch
Solenoid Coil
(4-way valve)
Pressure Sensor
(High Pressure)
Wear gloves to prevent the frostbite,
because a small amount of refrigerant leaks during work.
CAUTION
Remove the PRESSURE SENSOR with wrench.
Note the tightening torque at the installation.
Tightening torque is 15 1.5N m.
06-07
7-2.
SOLENOID COIL (4way valve) removal
Remove the mounting screw
with wrench or short screwdriver.
Remove the SOLENOID COIL.