15
-Note-
If the function you are selecting is restricted by [Management]
IXQFWLRQIROORZLQJPHVVDJHLVGLVSOD\HGLQWKHRSHUDWLRQJXLGDQFH
display. The message is displayed constantly during the management
function is enabled.
XXXXXX
XXXXXX
Restricted by the management function
Back:
12. OTHERS
12.1. Error code
,IDQHUURURFFXUVWKHSRZHULQGLFDWRUJUHHQEOLQNVDQGWKHIROORZLQJ
display will be shown.
If “Error”LVGLVSOD\HGLPPHGLDWHO\VWRSWKHDLUFRQGLWLRQHURSHUDWLRQDQG
consult authorized service personnel.
When there is an error on this remote controller:
Code : XXXXXX
Remote controller
Error
Mo
10:00
Error code
Without zone control
Error code Contents
Er 12.1
EE 1c
Wired remote controller communication error
Er 15.4
EE 1d
Incompatible indoor unit is connected
Indoor unit date acquisition error
Primary unit / Secondary unit setting error
Er CC.1
EE CC.1
Remote controller sensor error
With zone control
Error code Contents
Er 12.1
EE 1c
Wired remote controller communication error
&RPPXQLFDWLRQHUURUEHWZHHQLQGRRUXQLWDQG]RQH
FRQWUROLQWHUIDFH
&RPPXQLFDWLRQHUURUEHWZHHQ]RQHFRQWUROLQWHUIDFH
and remote controller
Indoor unit data acquisition error
Er 15.4
EE 1d
Incompatible indoor unit is connected
Indoor unit date acquisition error
Primary unit / Secondary unit setting error
Er CC.1
EE CC.1
Remote controller sensor error
When there is an error on the indoor unit:
Code : Er 41.1
R.C. address : 00
Error
Mo
10:00
Monitor
Code : XXXXXX
R.C. address : 00
Error
Mo
10:00
Monitor
Error code
Address number of the
relevant indoor unit