Troubleshooting
English
FAULT POSSIBLE REASONS TROUBLESHOOTING
No output voltage
No solar input or solar input
voltage too low
Check if the switch for the solar input
was turned on and that solar PV
system is properly connected.
Fault LED be red
Battery polarity reverse
Check the connection of the battery,
correct the connection if necessary.
PV reverse
Check the connection of the PV input,
correct the connection if necessary.
Battery over charge
Check if the battery is good, replace
the battery if necessary.
Battery disconnected
Check if the connection between
battery to charger is loose, reconnect
the battery if necessary.
Battery not fully charged
Too much load connects to the
battery
Remove the loads.
Battery temperature too low Use the battery temperature sensor.
Wrong battery type setting
Choose the correct battery type by
pressing the Battery Selection button.
Battery cable too small
Use larger gauge battery cable to
reduce the voltage drops.
Too little sun to power solar array Reposition vehicle, if applicable.
Battery not charged
Too much load connects to the
battery
Remove the loads.
Battery damaged
Check the battery, replace the battery
if necessary.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furrion FURRIONNET-ZERO FSCC60PWM-BL and is the answer not in the manual?

Furrion FURRIONNET-ZERO FSCC60PWM-BL Specifications

General IconGeneral
BrandFurrion
ModelFURRIONNET-ZERO FSCC60PWM-BL
CategoryController
LanguageEnglish

Related product manuals