3.2 Timer Control panel
In captain's cabin
Enable Light will lit, whenever the
watch safety system is activated
from captain’s cabin
If the pushbutton is pressed, the
audible alarm sound and all lamps
are illuminated in the panel for
test purposes.
Alarm light will flash in case the
watchkeeper has failed to
acknowledge the watch period
warning in 30 seconds or if any
alarm has not been acknowledged
on the bridge within 60 seconds
Buzzer will sound in case the
watchkeeper has failed to
acknowledge the watch period
warning in 30 seconds or if any
alarm has not been acknowledged
on the bridge within 60 seconds
The buzzer can only be
acknowledged on the bridge
Timer Set switch will activate the
watch safety system
The time period is selected with
intervals of 3, 6, 9 and 12 minutes