6
1.1.3 System with locally supplied monitor
Monitor requirements
This system requires a standard VGA monitor, connected to the interface unit IF-8000.
Supply monitor and interconnection cable locally. A D-sub 15P connector is required for
connection to the DATA/VIDEO OUT port on the IF-8000. Use the three rows-type D-sub
connector; not the two rows-type.
YES NO
The monitor should satisfy the specifications shown below.
VGA type
ANALOG RGB 0.7 Vpp, positive polarity
TLL level H, V, negative polarity
Mounting the control unit on a desktop
For the system which uses a locally supplied monitor, fix the control unit to the mounting
plate (supplied as accessories) as shown below. See the parts list FP06-01120 and outline
drawings at the back of this manual for details.
1. Fix the mounting plate to the mounting location with two tapping screws (5X20).
2. Fix the bracket to the control unit with two hex. screws (M4X12).
3. Insert screwdriver from the top of the mounting plate holes and then loosely fasten two
hex. screws (M4X12).
4. Attach the control unit to the mounting plate and then tightly fasten two hex. screws.
5. Attach two cosmetic caps to holes at the top of the mounting plate.
Cable entrance hole
Mounting
Plate
Cable
Tapping Screws (5X20)
Fasten the screws to fix
the bracket.
Bracket
Bracket
Set to the hex.
screws tightened
at step 3.
Cable can be passed this direction.
6. Attach hard cover to protect the control unit.
How to remove the hard cover
Place your thumbs at the locations shown with
circles in the illustration at right, and then lift the
cover while pressing it with your thumbs.