EasyManua.ls Logo

Furuno FA-170 - How to Set the Notification

Furuno FA-170
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. OPERATION
1-10
1.7 How to Set the Notification
The [NOTIFICATION SET] menu is used to set the following items:
Enable or disable the alert buzzer.
Notifications for received [ADDRESSED] and [BROADCAST] messages.
• Notifications for collision detection.
To change the settings in the [NOTIFICATION SET] menu, do the following:
1. Press the MENU/ESC key to open the main menu.
2. Select [USER SET], then press
the ENT/ACK key.
3. Select [NOTIFICATION SET],
then press the ENT/ACK key.
The [NOTIFICATION SET]
screen appears.
4. Select the [BUZZER] item be-
low [ALERT], then press the
ENT/ACK key. The settings
pop up window appears.
5. Select [ON] to enable the alert buzzer, or select [OFF] to disable the alert buzzer,
then press the ENT/ACK to confirm the setting.
6. Select the [ADDRESSED] item below [RX MESSAGE], then press the ENT/ACK
key. The settings pop up window appears.
7. Select the appropriate setting, referring to the table below, then press the ENT/
ACK key.
8. Set the notifications for [BROADCAST] RX messages and [COLLISION DETECT]
in the same manner.
9. Select the [CPA THREHOLD] item in [COLLISION DETECT], then press the ENT/
ACK key to show the setting window for [CPA THREHOLD] is as shown.
10. Press S or T to set a range, then press the ENT/ACK key. The available ranges
are 0.0 NM to 6.0 NM.
11. Select the [TCPA THREHOLD] item in [COLLISION DETECT], then press the
ENT/ACK key to show the setting window for [TCPA THREHOLD] is as shown.
Note: When both CPA and TCPA are below the [CPA THREHOLD] and [TCPA
THREHOLD] setting values, the collision alarms is available.
12. Press S or T to set a time, then press the ENT/ACK key. The available time is 0
min to 60 min.
13. Press the DISP key to close the menu.
Setting Description
POPUP + BUZZER Enable both the pop up indication and the buzzer.
POPUP Enable only the pop up indication. (No buzzer.)
OFF Disable notifications.
NOTIFICATION SET
[ALERT]
ADDRESSED
BUZZER
BROADCAST
[RX MESSAGE]
[COLLISION DETECT]
INDICATION
: CURSOR
: SELECT : BACK
ON
POPUP
POPUP + BUZZER
POPUP
ENT ENT
:
:
:
:
CPA THRESHOLD 6.0NM
:
TCPA THRESHOLD 60min
:

Table of Contents

Other manuals for Furuno FA-170