3. MAINTENANCE, TROUBLESHOOTING
3-10
3.8 How to Restore Default Settings
You may clear all or specific settings to start afresh with default settings. When all data
is cleared, the default settings for all items in the [USER SET] menu are restored. Ad-
ditionally all messages and the alert history are cleared. GPS data is also cleared;
however, MMSI and IMO numbers, ship’s name and call sign are not cleared.
1. Press the MENU/ESC key to open the menu.
2. Select [DIAGNOSTICS] then press the ENT/ACK key.
3. Select [CLEAR MEMORY] then press the ENT/ACK
key.
4. Select [CLEAR ALL], [CLEAR MONITOR SET] or
[CLEAR GPS] as appropriate then press the ENT/
ACK key. A confirmation pop up window appears.
5. Select [YES] then press the ENT/ACK key.
For [CLEAR ALL] and [CLEAR MONITOR SET], a beep sounds then the equip-
ment restarts.
3.9 AIS-SART Test Indication in Target List
The FA-170 can confirm if an AIS-SART station is functioning correctly. This test re-
quires message 1 data or Message 14 data. Note that this setting is deactivated when
the power is turned off.
Note: This function tests if an AIS-SART station is functioning correctly. It is not a
SART diagnostic tool for FA-170.
1. Press the MENU/ESC key to open the menu.
2. Select [USER SET], then press the ENT/ACK key.
3. Select [SART TEST], then press the ENT/ACK key.
4. Select [SHOW], then press the ENT/ACK key.
5. Press the DISP key to close the menu.
6. Press the DISP to show the [TARGET LIST]. If the [DANGEROUS TARGET] is
displayed, switch to the [TARGET LIST], referring to step 3 of section 1.8.2.
7. Select [SART] then press the ENT/ACK key to show detailed information for the
AIS-SART station.
8. Confirm that the [STATUS] field is showing "SART TEST".
CLEAR ALL Restores all settings to default, except items in the [INITIAL SET]
menu (MMSI No., IMO No., ship’s name and call sign, etc.)
CLEAR MONITOR
SET
Restore default settings for dimmer, contrast, key beep and noti-
fications.
CLEAR GPS Clears GPS Almanac to receive latest Almanac.
CLEAR MEMORY
CLEAR ALL
CLEAR MONITOR SET
CLEAR GPS
SHOW
HIDE
USER SET
KEY BEEP
AUTO SORT
TIME DIFF
ON
HIDE
+00 : 00
SART TEST
1
2
3
4
5
6
7
ON
NOTIFICATION SET
ACTIVATE
LONG RANGE SET

Table of Contents