3.4.4 TX on/off log
The [TX ON/OFF LOG] shows the date and time at which transmissions were started
or stopped. The time and date at which unit was turned off is also displayed.
1. Press the MENU/ESC key to open the main menu.
2. Select [DIAGNOSTICS] then press the ENT/ACK key.
3. Select [TX ON/OFF LOG] then press the ENT/ACK key.
The reasons which may be displayed are listed in the table below, along with their
meaning.
4. Press S or T to move the cursor and display other log entries.
The cursor selects two lines, as shown in reverse video in the figure above. The
contents of each log entry are:
Top line: Date and time at which transmission was turned off and reason trans-
mission was turned off.
Note: If transmission is turned off for more than 15 minutes, one of the reasons
listed below is displayed.
Bottom line: Date and time at which transmission was turned on.
5. Press the MENU/ESC key to return to the [DIAGNOSTICS] sub-menu.
Reason Meaning
POWER OFF Transmission disabled due to unit power off.
SILENT MODE Transmission disabled due to unit operating in SI-
LENT mode.
CH MANAGEMENT COMMAND Transmission disabled due to CH INFO receive
mode.
EQUIPMENT MALFUNCTION Transmission disabled due to equipment malfunc-
tion.
INVALID CONFIGURATION Transmission disabled due to invalid settings.
Reason Meaning
"POWER OFF" Transmission ceased as the power was turned
off.
"SILENT MODE" Transmission ceased due to activation of [SI-
LENT] mode.
"CH MANAGEMENT COMMAND" Transmission ceased due to current channel set-
tings.
"EQUIPMENT MALFUNCTION" Transmission ceased due to equipment fault.
"INVALID CONFIGURATION" Transmission ceased due to invalid settings.
TX ON/OFF LOG
: CURSOR
: BACK
ENT
- - / - - - / - - - - - - : - - : - -
30/APL/2015 8:35:00
29/APL/2015 8:35:00
29/APL/2015 17:20:00
28/APL/2015 17:20:00
27/APL/2015 17:20:00
CH MANAGEMENT COMMAND
CH MANAGEMENT COMMAND
CH MANAGEMENT COMMAND
38/APL/2015 8:35:00
37/APL/2015 8:35:00
TX-OFF REASON
008 / 020
TIME
[
UTC
]
TX-ON
EQUIPMENT MALFUNCTION