FURUNO
FA-170
SP - 2 E4490S01G
160415
Output ABK, ACA, ACS, ALC, ALF, ALR, ARC, EPV, HBT, LR1, LR2, LR3,
LRF, LRI, NAK, PIWWIVD, PIWWSPR, PIWWSSD, PIWWVSD,
SSD, TRL, TXT, VER, VDM, VDO, VSD
4.3 Proprietary sentences (output only)
PFEC LBK, AIcmd, idatr, ident, idfnc, pidat, pireq
4.4 IEC61162-450 transmission group
Input MISC, TGTD, SATD, NAVD, PROP
Output Arbitrary (default: TGTD)
4.5 Network function (except IEC61162-450)
Data format SNMP, HTTP, Syslog, Furuno Management Protocol (FMP)
Data sentences same as 4.2 sentences
5 POWER SUPPLY
3.1 Transponder unit 12-24 VDC: 6-3 A
3.2 Monitor unit 12 VDC: 0.3 A max. (supplied from transponder unit)
3.3 AC/DC power supply unit (PR-240, option)
100-115/200-230 VAC, 1 phase, 50/60 Hz
6 ENVIRONMENTAL CONDITIONS
6.1 Ambient temperature
GPS/VHF antenna -30°C to +70°C (storage: -30°C to +85°C)
Other units -15°C to +55°C
6.2 Relative humidity 93% or less at +40°C
6.3 Degree of protection
GPS/VHF antenna IP56
Transponder unit IP20, IP22 (bulkhead mount)
Monitor unit IP22, IP35 (option)
Pilot plug unit IP22 (front panel), IPX0 (chassis)
6.4 Vibration IEC 60945 Ed.4
7 UNIT COLOR
7.1 GPS/VHF antenna N9.5
7.2 Transponder/ Monitor unit N2.5
7.3 Pilot plug unit N2.5