2. WIRING
2-49
Connection of cables for serial, contact signal lines and sub monitors of EC-
DIS
1. Unfasten the four bolts dashed circled below to remove the upper plate of the ca-
ble clamp.
2. Remove the spacers to pass the appropriate cables on the upper and lower
plates. The recommended cable entrances are shown as below.
3. Fasten the cables to the post part of the plates with cable ties (local supply).
Note: Be sure the vinyl sheath on the post.
4. Pass the cables to the TB board 03P9648 and
03P9562 through the locking wire saddles (A, B and
C) in the figure shown right.
For the cables on the upper plate, use locking wire
saddles (A and B).
For the cables on the lower plate, use locking wire
saddles (A, B and C).
Upper
plate
Lower
plate
GPS HDG
LOG Control Unit
RS-232C
(for brill control)
Sub Monitor 1 of ECDIS
Sub Monitor 2 of ECDIS
(Antenna Unit)AIS ECDIS AD-10
AMS (Serial)
AMS (Contact)
Spacer
Cable tie
Ground termimal
Ground termimal
Cable tie
Vinyl
sheath
Shield
Cable tie
Sub monitor cable
Serial cable
Vinyl
sheath
Upper plate Lower plate
(
B
)
(
C
)
03P9648
03P9652
(
A
)