2. WIRING
2-31
2.7.1 MC-3000S
Use the LAN cable FR-FTPC-CY cable to connect the MC-3000S and the processor
unit. With HUB-100, a maximum of eight MC-3000S can be connected.
Fabrications
LAN cable (FR-FTPC-CY)
50
5050
30
3030
See section 2.1.2. for
the fabrication.
See section 2.1.2. for
the fabrication.
See section 2.1.2. for
the fabrication.
MC1.5-W-L600/1000/2000/3000 cable
100
100100
20
2020
10
1010
Core: 6
Core: 6Core: 6
Vinyl tape
Vinyl tapeVinyl tape
Shield
(fold back)
Shield
(fold back)
Shield
(fold back)
TTYCS-1Q cable
Core: 6
Core: 6Core: 6
(J8)
#1 to 4: 110
#5 to 8: 95
(J8)
#1 to 4: 110
#5 to 8: 95
(J8)
#1 to 4: 110
#5 to 8: 95
(J9)
#1 to 4: 100
#5 to 8: 90
(J9)
#1 to 4: 100
#5 to 8: 90
(J9)
#1 to 4: 100
#5 to 8: 90
30
3030
80 or
more
80 or
more
80 or
more
Shield (fold back)
Shield (fold back)Shield (fold back)
Vinyl tape
(width: 10)
Vinyl tape
(width: 10)
Vinyl tape
(width: 10)
TTYCSLA-1Q cable
Core: 6
Core: 6Core: 6
(J8)
#1 to 4: 110
#5 to 8: 95
(J8)
#1 to 4: 110
#5 to 8: 95
(J8)
#1 to 4: 110
#5 to 8: 95
(J9)
#1 to 4: 100
#5 to 8: 90
(J9)
#1 to 4: 100
#5 to 8: 90
(J9)
#1 to 4: 100
#5 to 8: 90
80 or
more
80 or
more
80 or
more
Vinyl tape
(width: 10)
Vinyl tape
(width: 10)
Vinyl tape
(width: 10)
60 mm:
Pass drain wire through
vinyl sheath (local supply),
then attach crimp-on lug
(pre-attached in unit).
60 mm:
Pass drain wire through
vinyl sheath (local supply),
then attach crimp-on lug
(pre-attached in unit).
60 mm:
Pass drain wire through
vinyl sheath (local supply),
then attach crimp-on lug
(pre-attached in unit).