5 POWER SUPPLY
5.1 Communication unit 12-24 VDC: 9.2-4.6 A (transmit), 2.0-1.0 A (receive)
5.2 Handset PD class 2, 5 W or less
5.3 Incoming indicator PD class 1, 2 W or less
5.4 AC/DC power supply unit (PR-240, option)
100-115/200-240 VAC, 1 phase, 50/60Hz
6 ENVIRONMENTAL CONDITION
6.1 Ambient temperature
Exposed equipment: -25°C to +55°C (storage: -40°C to +70°C)
Protected equipment: -25°C to +55°C
6.2 Relative humidity 95% at 40°C
6.3 Degree of protection
Antenna unit IP56
Communication unit IP22 (tabletop mount with a connector cover and grommets)
Handset IP22 (cradle: IPX0)
Incoming indicator IP22
6.4 Vibration IEC 60945
6.5 Motion Roll: ±30°/8s, Pitch: ±10°/6s, Yaw: ±8°/50s, Rotation: 6°/s,
Speed: 30 kn
7 UNIT COLOR
7.1 Antenna unit N9.5
7.2 Communication unit N2.5
7.3 Handset/ cradle N2.5
7.4 Incoming indicator N2.5