4.4 Updating Program
4-11
4.4.4 IB-583
According to the installed boot program, the procedure of updating differs as below.
- New boot program: Updating from the serial port, [DTE] and FDD
- Old boot program (shipping in 2002): Updating from the serial port, [DTE]
To distinguish the boot program, turn on IB-583 without the floppy disk in the floppy
disk drive. When the drive LED lights twice, the program is new. When lights once, the
program is old.
Updating from the serial port, [DTE]
1. Turn off IB-583.
2. Connect the PC. See 4.2.
3. Insert the floppy disk contains the latest program into the slot of the PC.
4. Double click the batch file icon of the program to be updated. When updating from
DOS window, type the batch file name.
5. The updating file runs automatically. No message appears on IB-583 display.
6. When the message “[Waiting For Target Wake up…] Time: x (sec)” appears, turn
on IB-583 within 25 seconds. If the message “Time Out Error!” appears, close the
display by pressing [C] while holding down [Ctrl], and repeat from step 4.
7. Updating automatically starts.
8. Updating is completed with “Update Complete”. Normal display appears on
IB-583.
9. Turn off the system and on it again.
To check the detail program number;
1) Run “Self test” of [F6] system menu.
2) Press [F1] while holding [Fn] and [Alt] to show the program version in detail.
Program to be updated Command
IB-583 UP583.BAT