3.3 DSC SETUP
3-17
EXT ALARM
The alarm sound from the incoming indicator (IC-303-DSC) is switched to ON or OFF
according to the category of the DSC message. See table below.
Table 3.3.2 EXT ALM and category
Options
Category
DISTRS ROUTINE ALL OFF
DISTRESS ON OFF ON OFF
URGENCY ON OFF ON OFF
SAFETY OFF OFF ON OFF
BISINESS OFF ON ON OFF
ROUTINE OFF ON ON OFF
2. AUTO ACK
Figure below shows “Auto ack setup” menu.
COMPLY TYPE
At the reception of Individual, PSTN, Position and Polling calls, acknowledgement can
be sent out automatically with the selected comply type (able or unable). AUTO ACK is
selected by using [ACK].
· ABLE: Able to comply
· UNABLE: Unable to comply
In Auto ACK mode, acknowledgement is not sent out automatically;
· When the received message includes an error (ECC ERROR).
· When the handset is “OFF HOOK”.
· When “COMPLY TYPE “ is “UNABLE” where as the setting of “POLLING
and “POSITION CALL” is ON.
· When the category is distress, urgent and safety.
· When the communication type is TTY, MORSE, FAX and DATA
· When the communication frequency is set to “No Information” or specified
other than marine band.
· When either transmission or receiving frequency is not specified.