3.3 DSC SETUP
3-23
J6
J3
J2
J5
05P0732
S5
S4
S2
S3
J4
J1
S6
S7
5. POSITION
When position data is received from EPFS, INPUT TYPE is set to AUTO. The
receivable IEC-61162-1 and NMEA (Ver-2.0 or above) sentences are GGA>RMC>GLL
(position) and ZDA (time).
The position data input by MANUAL setting has higher priority than the one input by
AUTO setting.
“Invalid” position data is not received.
The position data is used in Distress, Individual and Position Call messages. The data is
automatically erased and “Warning: Update position” message appears when it is not
updated for 23.5 hours. EPFS error message is displayed and the alarm sound is
released when EPFS data is interrupted for one minute.
DIP switch Setting
The DIP switch S2 on T-CPU board sets the interface type to either RS-422 or current
loop.
RS-422
(IEC-61162-1)
C.Loop
S2-#1 ON OFF