2-6
IEC61162-1 (NMEA) equipment
Connects a navigator to the terminal box in the transceiver unit. The FS-1570/2570 can
receive the following sentences in IEC-61162-1 (ed.2nd) format. Use the interconnection
cable type CO-SPEVV-SB-C 0.2x2P (option).
GLL: Latitude and longitude
RMC: Generic navigation information
GGA: GPS position, UTC
ZDA: UTC, day, month, and year
RMA: Minimum Loran-C data
Priority: GGA>RMC>GLL Priority is kept for one minute.
TLL (Lat./Long. of ship in distress) can be output to the navigator connected.
Distress alert IC-302
Use CO-SPEVV-SB-0.2X5P cable (option). For the fabrication, see the figure in below.
Indicator IC-303
Use CO-SPEVV-SB-C 0.2X5P cable (option) and fabricate it as below.
45
11
9
Outer sheath
Twist and trim the shield.
Inner sheath
Remove the outer sheath and
armor by 45 mm.
Remove the inner sheath by 14 mm,
and the sheath of the cores by 3 mm.
Cut the unused cores.
Solder a vinyl wire to the shield.
Vinyl wire
Fabrication of CO-SPEVV-SB-C for connect to the transceiver unit