2. MAINTENANCE
2-12
3. When the remote analysis finishes, the message "Remote Analysis Finished" ap-
pears. Press any key to clear the window.
2.4 Fuse Replacement
The DCU VR-7010, Video LAN Converter IF-7100 and Sensor Adapter MC-3000S
have fuses that protect them from high electric current and equipment fault. If you can-
not turn on the power to a unit, check its fuse to see if it has blown. If the fuses for the
DCU have blown, replace them with the specified fuses (see page AP-3 for the fuse
location). If the fuses blow again after replacement, contact a FURUNO agent or deal-
er. Have a qualified technician replace the fuse for Video LAN Converter and Sensor
Adapter.
Unit Name Type Code No. Remarks
VR-7010 Glass Tube Fuse FGBO-A 250V 10A PBF 000-155-839-10
For battery
For AC power
IF-7100 Glass Tube Fuse FGMB-A 125V 2A PBF 000-157-479-10
MC-3000S Glass Tube Fuse FGMB-A 125V 3A PBF 000-157-481-10