Gator Automatic Butt Fusion Range
Operating Manual
EDOI6922 Page 30 of 44 Issue 02
Mode
Message
Reason
Possible cause
Remedy
31
Heater UP/DOWN status
The machine has detected
that the heater is not up.
Faulty heater plate detection
switch.
Contact dealer
32
Abort during dwell
Dwell phase aborted
Emergency stop button pressed
Power failed
Ensure generator has enough fuel. Do not
switch off during process
33
Abort during beadup
(Expansion)
Expansion phase aborted
Emergency stop button pressed
Power failed
Ensure generator has enough fuel. Do not
switch off during process