Use and Maintenance Manual – Pressure-sensitive bumpers type GSBPS 15/35
5.2 Technical Specifications of sensors
Actuation force with Φ80mm at 10
mm/s
Actuation force with Φ80mm at 100
mm/s
Response time (max) (constant speed
100 mm/s specimen 1, point 3)
<200 ms with Gamma System devices
4x0,35mm
2-
standard length 3 m
4x1 mm
2
–standard length>20 m (max 100 m)
Operating and storage temperature of
sensor
Density of foamed material
Degree of Protection (according to EN
60529 Standard) of the sensor
Tests made in conformity with EN ISO 13856-3 Standard
Sensor+control unit parameters
T
10D
[years] control unit***
* Maximum length for mounted sensor = 3000 mm. For larger sizes, division in several parts is possible by connecting
the sensors in series.
** For lengths higher than 20 m, use cables with1 mm
2
section (max 100 m)
***Max number of operations. Once time indicated has elapsed, contact Gamma System.
Remark: for the characteristics of the control unit, please refer to point 16.
Recovery after deformation:
For deformation equal to the operating travel equivalent to 250N force applied throughout 24 hours, the
change in depth is: less than 20 % after 30 sec.; less than 10 % after 5 min. and less than 5% after 30 min.