GAT ECO.Side Lock 7010 (NW) F/ISO
Commissioning
46
HB_GAT-ECOSide-Lock7010-FISO--EN_11
www.gantner.com
5.4.5 Auto-Unlock
The auto-unlock function automatically unlocks the GAT ECO.Side Lock 7010 F/ISO at a defined point in time. The
time must be set correctly once via software.
NOTE! When this function is activated, the lock will always unlock at the defined point of time regardless of the
operating mode (see “6.3 Operating Modes”).
The auto-unlock function is found here:
Configuration > Operating mode > General > AutoUnlock [min]
Enter a value representing the number of minutes into the field. The countdown time for unlocking begins at
00:00 (24 h). For example, a value of “300” means that the lock will unlock at 05:00 am. A value of “0” means
that the function is inactive.
5.4.6 Duration of Use
Lockers operating in free locker mode can be configured to limit the user to a defined period of use. See section
6.3.1. Free Locker Mode (with or without Duration of Use Function)for detailed information. The duration of use
function is found here:
Configuration > Operating mode > Free Locker
Select either “Duration” or “Point of time” from the “Use time limit” menu for the type of time limit.
Define the time limit in minutes in the “Time limit (min)” field.
5.4.7 Locking of Personal Locker without Data Carrier
The functionality of locking personal lockers without data carriers allows the locker to lock automatically when the
locker door is pushed shut, without needing to use a data carrier. The locker can be unlocked again using the data
carrier(s) authorized to use the personal locker. The function is found here:
Configuration > Operating mode > Personal Locker > PreLock Personal Locker
Select / deselect the “PreLock Personal Locker” option to turn the function on / off.
5.4.8 RF Standards
The GAT ECO.Lock 7010 F/ISO can operate with data carriers that use ISO 15693 and ISO 14443A (MIFARE)
technology.
The default setting for the GAT ECO.Lock 7010 F/ISO is to operate with ISO 14443A (MIFARE) data carriers.
The setting for the GAT ECO.Lock 7010 F/ISO to operate with ISO 14443A (MIFARE) data carriers cannot be
changed. The setting for the GAT ECO.Lock 7010 F/ISO to operate with ISO 15693 data carriers can be adjusted
and is found here:
Configuration > Reader > RF Standards > ISO 15693
Select / deselect the “ISO 15693” option to turn the function on / off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gantner GAT ECO.Side Lock 7010 F/ISO and is the answer not in the manual?

Gantner GAT ECO.Side Lock 7010 F/ISO Specifications

General IconGeneral
BrandGantner
ModelGAT ECO.Side Lock 7010 F/ISO
CategoryLocks
LanguageEnglish

Related product manuals