Testing the reader 37
such an alarm is present, refer to the troubleshooting
guide at the end of this manual.
Note: In silent supervised mode, no indication of loss of
supervision is provided, except badges will not be read.
7. Select a known good ProxLite test badge. Be sure the
badge is properly entered in the host system, and the
micro badge data format matches the reader. If the reader
is used with a keypad (Models 972 and 973 only), assign
a proper PIN.
8. Check that the door is secure. Present the badge to the
reader. Observe that the reader beeps briefly and the
yellow LED blinks off.
9. If the reader is used with a keypad (Models 972 and 973
only), enter a PIN. Refer to the host manual for
instructions on entering the PIN. Observe that the green
LED turns on indicating a valid access has been granted
by the host.
10. Open the door. This verifies that the door strike operates
correctly.