Installation
Instructions
UL-LISTED
FLEXIBLE
METAL
(SEMI-RIGID}
TRANSITION
DUCT
*lf
rigid
metal
duct
cannot
be
used,
then
UL-listed
flexible
metal
(semi-rigid)
ducting
can
be
used
(Kit
WX08x10077).
*
Never
install
flexible
metal
duct
in
walls,
ceilings,
floors
or
other
enclosed
spaces.
*
Total
length
of
flexible
metal
duct
should
not
exceed
8
feet
(2.4m).
*For
many
applications,
installing
elbows
at
both
the
dryer
and
the
wall
is
highly
recommended
(see
illustrations
below}.
Elbows
allow
the
dryer
to
sit
close
to
the
wall
without
kinking
and
or
crushing
the
transition
duct,
maximizing
drying
performance.
e
Avoid
resting
the
duct
on
sharp
objects.
UL-LISTED
FLEXIBLE
METAL
(FOIL-TYPE)
TRANSITION
DUCT
ein
special
installations,
it
may
be
necessary
to
connect
the
dryer
to
the
house
vent
using
a
flexible
metal
(foil-type)
duct.
A
UL-listed
flexible
metal
(foil-type)
duct
may
be
used
ONLY
in
installations
where
rigid
metal
or
flexible
rnetal
(semi-rigid)
ducting
cannot
be
used
AND
where
a
4”
diameter
can
be
maintained
throughout
the
entire
length
of
the
transition
duct.
ein
Canada
and
the
United
States,
only
the
flexible
metal
(foil-type}
ducts
that
comply
with
the
“Outline
for
Clothes
Dryer
Transition
Duct
Subject
2158A”
shall
be
used.
*
Never
install
flexible
retal
duct
in
walls,
ceilings,
floors
or
other
enclosed
spaces.
*
Total
length
of
flexible
metal
duct
should
not
exceed
8
feet
(2.4m).
*
Avoid
resting
the
duct
on
sharp
objects.
For
best
drying
performance:
1.
Slide
one
end
of
the
duct
over
the
clothes
dryer
outlet
pipe.
2.
Secure
the
duct
with
a
clamp.
3.
With
the
dryer
in
its
permanent
position,
extend
the
duct
to
its
fulllength.
Allow
2”
of
duct
to
overlap
the
exhaust
pipe.
Cut
off
and
remove
excess
duct.
Keep
the
duct
as
straight
as
possible
for
maximum
airflow.
4.
Secure
the
duct
to
the
exhaust
pipe
with
the
other
clamp.
ELBOW
REQUIRED
SIT
DRYER
ON
FLEXIBLE
EXHAUST
vs
Se
DO
NOT
USE
EXCESSIVE
EXHAUST
LENGTH
DO
NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
WALL
LEVELING
AND
STABILIZING
YOUR
DRYER
Stand
the
dryer
upright
near
the
final
location
and
adjust
the
4
leveling
legs,
at
the
corners,
to
ensure
that
the
dryer
is
level
from
side
to
side
and
front
to
rear.
LEVEL
4
LEVELING
LEGS
[9]
ALCOVE
OR
CLOSET
INSTALLATION
elf
your
dryer
is
approved
for
installation
in
an
alcove
or
closet,
it
will
be
stated
on
a
label
on
the
dryer back.
«The
dryer
MUST
be
vented
to
the
outdoors.
See
the
EXHAUST
INFORMATION
step
6.
«Minimum
clearance
between
dryer
cabinet
and
adjacent
walls
or
other
surfaces
is:
O
in.
either
side
3
in.
front
3
in.
rear
¢
Minimum
vertical
space
from
floor
to
overhead
cabinets,
ceiling,
etc.
is
52
in.
*Closet doors
must
be
louvered
or
otherwise
ventilated
and
must
contain
a
minimum
of
60
sq.
in.
of
open
area
equally
distributed.
If
the
closet
contains
both
a
washer
and
a
dryer,
doors
must
contain
a
minimum
of
120
sq.
in.
of
open
area
equally
distributed.
eThe
closet
should
be
vented
to
the
outdoors
to
prevent
gas
pocketing
in
case
of
a
gas
leak
in
the
supply
line.
@No
other
fuel-burning
appliance
shall
be
installed
in
the
same
closet
with
the
dryer.
NOTE:
WHEN
THE
EXHAUST
DUCT
IS
LOCATED
AT
THE
REAR
OF
THE
DRYER,
MINIMUM
CLEARANCE
FROM
THE
WALL
tS
5.5
in.