53
WavePro
Breaker Catalog Number Guide
WE2DAQD
1234567
Trip unit codes (See Table A)
TU function Code
none X
LS
Á
A
LSG
Â
B
LSGZ1
Â
C
LSGZ2
Â
D
LSGD
¬ Â
E
LSGDZ1
¬ Â
F
LSGDZ2
¬ Â
G
LI
Á
J
LIG
Â
K
LIGZ1
Â
L
LIGD
¬ Â
M
TU function Code
LIGDZ1
¬ Â
N
LSI
Á
P
LSIG
Â
Q
LSIGX
¬ Â
R
LSIGZ1
Â
S
LSIGZ2
Â
T
LSIGD
¬ Â
V
LSIGDZ1
¬ Â
W
LSIGDZ2
¬ Â
Y
¬ Not UL Listed
Á
Power+ available with LI, LS or LSI only
 GF is 3w/4w (See Note 1 below)
Rating
Sensor
Plug
Code
none X
60
¬
1
80 2
150 100 3
125
4
150 5
150
¬
5
200 6
400
225
7
250 8
300 9
400 A
300
¬
9
800 400 A
450
¬
B
500 C
Rating
Sensor
Plug
Code
600 D
800 700 E
800 G
600
¬
D
800
G
1600 1000 H
1100
¬
J
1200 K
1600
M
750
¬
F
800
¬
G
1000 H
2000 1200 K
1500
¬
L
1600 M
2000 N
Rating
Sensor
Plug
Code
1200 K
3200 1600 M
2400 P
3200 S
1600
M
2000 N
4000
2500
Q
3000 R
3600
¬
T
4000 V
3200
¬
S
5000 4000
¬
V
5000
¬
W
¬
Rating plug value not
available on Power+
trip unit
Usage Code
AKD10/PBII/AV3 Access Equipment WE
Special “dead front shield” for use in W1
AKD-10/PBII/AV3 Access Equipment
Interrupting Capability/ Silver
Fuse Type Code “L” Fuse
Standard (ex. WPS) 1
High (ex. WPH) 2
Extended (ex. WPX) 3
OFLO only 4
300A Class “J” fuse A
350A Class “J” fuse B
400A Class “J” fuse C
450A Class “J” fuse D
500A Class “J” fuse E
600A Class “J” fuse F
800A Class “L” fuse G 5
1000A Class “L” fuse H 6
1200A Class “L” fuse J 7
1600A Class “L” fuse K 8
2000A Class “L” fuse L 9
2500A Silver “L” fuse M
800A “Welder” limiter N
1200A “Welderlimiter P
1600A “Welderlimiter Q
2000A “Welderlimiter R
Frame & Sensor Code (See Note 1)
800
none
A
150 B
400 C
800 D
1600 none E
800 F
1600 G
2000
none H
2000 J
3200
none
K
3200 L
4000 none M
4000
N
5000 none P
5000 R
Trip Unit type Code
none (non-automatic) X
MVT Plus A
MVT M (metering & communications) B
MVT PM (relaying, metering
& communications) C
MVT Plus (w/special GF curve) D
MVT M (w/special GF curve) E
MVT PM (w/special GF curve) F
Power +
¬
G
Power + (w/GF)
¬ Â
H
Power + (w/Defeatable GF)
¬ Á Â
J
Power + (w/targets)
¬
K
Power + (w/targets & GF)
¬ Â
L
Power + (w/targets &
Defeatable GF)
¬ Á Â
M
¬
Power + is not available for 5000A frame breakers
Á
Not UL Listed
Â
G
F is 3w/4w (See Note 1 below)
Table A
L = Long Time (LT)
S = Short Time (ST)
I = Instantaneous (Inst)
G = Ground Fault (GF)
GD= Defeatable GF
X = Switchable ST or Inst and GF
Z1 = Zone Selective Interlocking—GF
Z2 = Zone Selective Interlocking—
GF and ST
Note 1: If 4 wir
e GF is r
equir
ed then the "A-Disc" [character position 14] must
be selected and the 4th wir
e (neutral) sensor must be or
der
ed separately.
R
efer to DEP-080 Pr
oduct Catalog.
Sensor = "none" for non-automatic breakers
Equipment Usage Frame Sizes & Interrupting Rating Trip Unit Type, Characteristics & Trip Rating
S
T
Fuse Link
U
on
V
Phase B
W
Y

Related product manuals