Factory Test Mode
The air conditioner has a factory mode function that allows the service technician to test various
functions.
Note: The factory test mode cannot be entered if the unit has shut down due to high water (see Float
Switch Operation under
Circulation Pump). Unplug the unit and drain the sump before entering factory
test mode.
• To enter the factory test mode, unplug the unit, then plug it back in while simultaneously pressing
and holding the ON button.
• While the ON button is still pressed, the software checks the 2 thermistors for open/short conditions.
If the thermistor is open, the power supply board beeps. After this initial test, all the functions can
then be tested. (Overcool protection and compressor protection are disabled on the compressor.)
• To exit the factory test mode, unplug the unit.
Function Key -
Electronic Mode
Status /
Function
Display Action Notes
On/Off On
Appropriate symbol of Fan
or Cool and Temperature
Unit powered up, compressor
On / fan On. When restarted,
the compressor will stay off for 3
minutes
On/Off Off Nothing displayed Unit unpowered
Temperature Button
Increase /
Decrease
Desired Room
Temperature
Cool Symbol and Desired
Temperature
Desired air temperature is set
& discharged from unit. Fan
and compressor cycle until set
temperature is received by temp
sensor.
Temperature is not displayed in
Fan Mode.
Fan Speed Button
Increase /
decrease
Desired Fan
Speed
Fan Symbol or LED and
Desired Fan Speed (F1, F2
& F3 or Low, Med & High)
Desired fan speed (RPM) is set &
fan motor speed changes
In Fan Only mode, fan symbol
and speed will stay on display. In
Cool Mode, fan speed will briefl y
appear on display then display will
revert to temperature setting.
Mode Button
Changes
unit function
between Fan
Only and Cool
Mode
Appropriate symbol of Fan
or Cool or LED
In Cool Mode, the unit fan and
compressor run and cool air is
discharged from unit. In Fan Mode,
the compressor is OFF and fan
runs at set speed to circulate
ambient temperature air in room.
Timer Button On
Timer symbol or LED On
with time count (1 - 12 or 1
- 24 hrs.)
Time Function is set.
Time Function can be set so that
the unit can be made to run or
shut down with timer.
Timer Button Off Nothing Displayed N / A
Energy Saver On / Off On
Energy Saver Symbol (or
LED) and Temperature
In this mode the fan runs at
a reduced RPM when the
compressor shuts off. When the
compressor restarts, the fan RPMs
change back to the desired setting.
Energy Saver On / Off Off
Standard mode and function
symbol
Standard Cool Cycle mode and
function
Circulaire
Engages
motorized
air discharge
louvres
May have a Circulaire
symbol or LED display
Motorized louvres begin auto swing
sequence
Sleep Mode
Button activates
Sleep Mode
Sleep symbol (or LED)
displayed for 15 seconds
after key is depressed
Unit runs for 8-hour cycle when
sleep key is pressed. One hour
after, cycle start temperature
increases a minimum 2°F to a
maximum of 4°F from the set point
for the duration of the cycle.
Key Function Chart