Auxiliary controlson your Zoneline.
I MODE31
[ MODE 4
[ MODE 5
[ MODE 6
Freeze Sentinel/Heat Sentinel
Inthe defaultsettingfor Mode3,HeatSentinelisoff, Freeze
Sentinelis on.
PressMODEuntila 3appearsinthefirstdigitof the displayfor
FreezeSentinelmode.TheCOOL.LEDlightqnthemaincontrol.
willbeon.PressHQDEagaintochanqeto the HeatSentinel.The
HEATLEDlightonthemaincontrolw_lbeon.Pressthe down
arrowfor OFF"u "or theuparrowforON"n." Thisisshown
inthesecond`digitatthedisplay.PressAUXSETto contirmyour
selectionandexitAUXSETmode,or pressMODEtocontinue
settingotherfunctions.
VhenFreezeSentinelis activated,it automaticallyprovides
eatwithout userinterface.Thishelpsto preventplumbing
damagebyturningthe heaterandindoorfan ONat 41%and
OFFat 46%.
WhenHea_Sentinelis activated,it automaticallyprovides
coolingwithout userinterface.Thishelpsto preventan
excessivelyhot room by turningtheair conditionerONat85%
andOFFat 80°F.
NOTE:Thesefunctionsare activewheneverthe unitis
pluggedin,evenifthe unit isin the STOPposition.
HIGH
U --LOW
-- AUTO
FreezeSentinelOFF
3B_ HIGH
-- LOW
-- AUTO
FreezeSentinelON
HIGH
U --LOW
-- AUTO
HeatSentinelOFF
3b'_ HIGH
-- LOW
-- AUTO
HeatSentinelON
Constant ON Fan
Thedefaultsettingfor Mode4 isOFF.
PressMODEuntila4 appearsin thefirstdigitofthe displayto set
thefan to runcontinuouslyat highspeed,eveniftheunitisin
theSTOPposition.PressthedownarrowforOFF"u" ortheup
arrowfor ON"n." Thisisshownin the seconddigitofthe
display.PressAUXSETto confirmyour selectionandexitAUX
SETmode,or pressMODEto continuesettingotherfunctions.
h
Constant Constant
FanOFF FanON
Temperature Limiting
Thedefault settinqfor Mode5 isasfollows:
Cool:0 (60%to 8_°F}
Heat:7 (60%to 85°F}
PressMODEuntila5 appearsin thefirstdigitofthe displayfor
TemperatureLimitingcool.mode.Th,eCOOLt_EDlightonthe
maincontrolwill belit.Tochange.toheatmode,pressMODE
agai.nandtheHEATnEDlightonthemaincontrolwill belit.To
setthetempeEaturelimits,pressthe upordownarrow keys.The
seconddigit atthedisplaywillbebel_ween0 and7 dependingon
thelimityouwantto set.Thechartshowsthe limitsavailable.
PressAUXSETto confirmyourselectionandexitAUXSETmode,
or pressMODEto continuesettingotherfunctions.
Temperaturelimits--Cool Temperaturelimits--Heat
0 = 60°Fto 85% 0 = 60% to 65%
1 = 64°Fto 85% 1 = 60% to 70%
2= 66°Fto 85% 2 = 60% to 72%
3 = 68°Fto 85% 3 = 60% to 74%
4= 70°Fto 85% 4 = 60% to 76%
5 = 72°Fto 85% 5 = 60% to 78%
6 = 74°Fto 85% 6 = 60% to 80°F
7 = 76°Fto 85% 7 = 60% to 85%
_COOL
-- FAN
-- HEAT
_COOL
-- FAN
-- HEAT
Remote Thermostat - Class 2
Thedefaultsettingfor Mode6is OFF.
Settingthismodeto ONwillallowthe unittooperate.witha Class
2 RemoteContro/WallThermostat:PressNODEuntil a6 appears
inthefirstdigitotthe displayfor Class2 mode.Pressthedown
arrowto turn theoptionOFF"u." Pressthe uparrowto turn this
optionON"m." Thisis shownintheseconddigitotthe display.
PressAUXSETtoconfirmyourselectionandexitAUXSETmode,
or pressMODEto continuesettingotherfunctions.
--COOL
-- FAN
HEAT
--COOL
-- FAN
HEAT
C Cn
Class2OFF Class2 ON
HIGH --COOL
53 --LOW --FAN
--AUTO reHEAT
TemperatureLimitingHeat- Limit3
_ HIGH _ COOL
_# _ -- LOW -- FAN
--AUTO --HEAT
TemperatureLimitingCool- Limit2