GE Multilin B30 Bus Differential System B-45
APPENDIX B B.4 MEMORY MAPPING
B
8613 Breaker Failure 1 Breaker Status 2 Phase A/3P 0 to 4294967295 --- 1 F300 0
8615 Breaker Failure 1 Breaker Test On 0 to 4294967295 --- 1 F300 0
8617 Breaker Failure 1 Phase Amp Hiset Pickup 0.001 to 30 pu 0.001 F001 1050
8618 Breaker Failure 1 Neutral Amp Hiset Pickup 0.001 to 30 pu 0.001 F001 1050
8619 Breaker Failure 1 Phase Amp Loset Pickup 0.001 to 30 pu 0.001 F001 1050
861A Breaker Failure 1 Neutral Amp Loset Pickup 0.001 to 30 pu 0.001 F001 1050
861B Breaker Failure 1 Loset Time 0 to 65.535 s 0.001 F001 0
861C Breaker Failure 1 Trip Dropout Delay 0 to 65.535 s 0.001 F001 0
861D Breaker Failure 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
861E Breaker Failure 1 Events 0 to 1 --- 1 F102 0 (Disabled)
861F Breaker Failure 1 Phase A Initiate 0 to 4294967295 --- 1 F300 0
8621 Breaker Failure 1 Phase B Initiate 0 to 4294967295 --- 1 F300 0
8623 Breaker Failure 1 Phase C Initiate 0 to 4294967295 --- 1 F300 0
8625 Breaker Failure 1 Breaker Status 1 Phase B 0 to 4294967295 --- 1 F300 0
8627 Breaker Failure 1 Breaker Status 1 Phase C 0 to 4294967295 --- 1 F300 0
8629 Breaker Failure 1 Breaker Status 2 Phase B 0 to 4294967295 --- 1 F300 0
862B Breaker Failure 1 Breaker Status 2 Phase C 0 to 4294967295 --- 1 F300 0
862D ...Repeated for Breaker Failure 2
865A ...Repeated for Breaker Failure 3
8687 ...Repeated for Breaker Failure 4
86B4 ...Repeated for Breaker Failure 5
86E1 ...Repeated for Breaker Failure 6
FlexState Settings (Read/Write Setting)
8800 FlexState Parameters (256 items) 0 to 4294967295 --- 1 F300 0
Digital Elements (Read/Write Setting) (48 modules)
8A00 Digital Element 1 Function 0 to 1 --- 1 F102 0 (Disabled)
8A01 Digital Element 1 Name --- --- --- F203 “Dig Element
1“
8A09 Digital Element 1 Input 0 to 4294967295 --- 1 F300 0
8A0B Digital Element 1 Pickup Delay 0 to 999999.999 s 0.001 F003 0
8A0D Digital Element 1 Reset Delay 0 to 999999.999 s 0.001 F003 0
8A0F Digital Element 1 Block 0 to 4294967295 --- 1 F300 0
8A11 Digital Element 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
8A12 Digital Element 1 Events 0 to 1 --- 1 F102 0 (Disabled)
8A13 Digital Element 1 Pickup LED 0 to 1 --- 1 F102 1 (Enabled)
8A14 Reserved (2 items) --- --- --- F001 0
8A16 ...Repeated for Digital Element 2
8A2C ...Repeated for Digital Element 3
8A42 ...Repeated for Digital Element 4
8A58 ...Repeated for Digital Element 5
8A6E ...Repeated for Digital Element 6
8A84 ...Repeated for Digital Element 7
8A9A ...Repeated for Digital Element 8
8AB0 ...Repeated for Digital Element 9
8AC6 ...Repeated for Digital Element 10
8ADC ...Repeated for Digital Element 11
8AF2 ...Repeated for Digital Element 12
8B08 ...Repeated for Digital Element 13
8B1E ...Repeated for Digital Element 14
8B34 ...Repeated for Digital Element 15
Table B–10: MODBUS MEMORY MAP (Sheet 37 of 64)