B-42 C60 Breaker Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
6894 Autoreclose Mode Aut 0 to 3 --- 1 F622 0 (Mode 1 (1 & 3
Pole))
6895 Autoreclose Mode 1 Activation 0 to 4294967295 --- 1 F300 0
6897 Autoreclose Mode 2 Activation 0 to 4294967295 --- 1 F300 0
6899 Autoreclose Mode 3 Activation 0 to 4294967295 --- 1 F300 0
689B Autoreclose Mode 4 Activation 0 to 4294967295 --- 1 F300 0
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
7000 Phase Undervoltage 1 Function 0 to 1 --- 1 F102 0 (Disabled)
7001 Phase Undervoltage 1 Signal Source 0 to 5 --- 1 F167 0 (SRC 1)
7002 Phase Undervoltage 1 Pickup 0 to 3 pu 0.001 F001 1000
7003 Phase Undervoltage 1 Curve 0 to 1 --- 1 F111 0 (Definite Time)
7004 Phase Undervoltage 1 Delay 0 to 600 s 0.01 F001 100
7005 Phase Undervoltage 1 Minimum Voltage 0 to 3 pu 0.001 F001 100
7006 Phase Undervoltage 1 Block 0 to 4294967295 --- 1 F300 0
7008 Phase Undervoltage 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
7009 Phase Undervoltage 1 Events 0 to 1 --- 1 F102 0 (Disabled)
700A Phase Undervoltage 1 Measurement Mode 0 to 1 --- 1 F186 0 (Phase to
Ground)
700B Reserved (6 items) 0 to 1 --- 1 F001 0
7011 ...Repeated for Phase Undervoltage 2
7022 ...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting) (3 modules)
7040 Phase Overvoltage 1 Function 0 to 1 --- 1 F102 0 (Disabled)
7041 Phase Overvoltage 1 Source 0 to 5 --- 1 F167 0 (SRC 1)
7042 Phase Overvoltage 1 Pickup 0 to 3 pu 0.001 F001 1000
7043 Phase Overvoltage 1 Delay 0 to 600 s 0.01 F001 100
7044 Phase Overvoltage 1 Reset Delay 0 to 600 s 0.01 F001 100
7045 Phase Overvoltage 1 Block 0 to 4294967295 --- 1 F300 0
7047 Phase Overvoltage 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
7048 Phase Overvoltage 1 Events 0 to 1 --- 1 F102 0 (Disabled)
7049 ...Repeated for Phase Overvoltage 2
7052 ...Repeated for Phase Overvoltage 3
Breaker Arcing Current Settings (Read/Write Setting) (4 modules)
7290 Breaker 1 Arcing Amp Function 0 to 1 --- 1 F102 0 (Disabled)
7291 Breaker 1 Arcing Amp Source 0 to 5 --- 1 F167 0 (SRC 1)
7292 Breaker 1 Arcing Amp Init 0 to 4294967295 --- 1 F300 0
7294 Breaker 1 Arcing Amp Init B 0 to 4294967295 --- 1 F300 0
7296 Breaker 1 Arcing Amp Init C 0 to 4294967295 --- 1 F300 0
7298 Breaker 1 Arcing Amp Delay 0 to 65.535 s 0.001 F001 0
7299 Breaker 1 Arcing Amp Limit 0 to 50000 kA2-cyc 1 F001 1000
729A Breaker 1 Arcing Amp Block 0 to 4294967295 --- 1 F300 0
729C Breaker 1 Arcing Amp Target 0 to 2 --- 1 F109 0 (Self-reset)
729D Breaker 1 Arcing Amp Events 0 to 1 --- 1 F102 0 (Disabled)
729E ...Repeated for Breaker 2 Arcing Amp
72AC ...Repeated for Breaker 3 Arcing Amp
72BA ...Repeated for Breaker 4 Arcing Amp
Disconnect (Breaker) Switch (Read/Write Setting) (16 modules)
74A0 Disconnect Switch 1 Function 0 to 1 --- 1 F102 0 (Disabled)
74A1 Disconnect Switch 1 Name --- --- --- F206 “SW 1"
74A4 Disconnect Switch 1 Mode 0 to 1 --- 1 F157 0 (3-Pole)
74A5 Disconnect Switch 1 Open 0 to 4294967295 --- 1 F300 0
74A7 Disconnect Switch 1 Block Open 0 to 4294967295 --- 1 F300 0
74A9 Disconnect Switch 1 Close 0 to 4294967295 --- 1 F300 0
74AB Disconnect Switch 1 Block Close 0 to 4294967295 --- 1 F300 0
74AD Disconnect Switch 1 Phase A / Three-pole Closed 0 to 4294967295 --- 1 F300 0
Table B–10: MODBUS MEMORY MAP (Sheet 34 of 66)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT