– 48 –
Thermistor
The 7KHUPLVWRULVORFDWHGLQVLGHWKHÀRRGVZLWFK
assembly. The thermistor monitors water
temperature in the tub. If the thermistor opens
or shorts it will cause a error (see Consumer Error
Mode). If it fails in open or shorted, the control will
default to the longest time algorithm
7RFKHFNWKHWKHUPLVWRUWKHÀRRGVZLWFKFDQEH
removed or checked by accessing the Main Control
(see To Access Main Control Board section), check
resistance on connector J711, pin 6 and pin 7.
Thermistor Strip Circuit
Flood Switch Pins
7KHUPLVWRU6SHFL¿FDWLRQV
Fill Funnel and Hose
The Fill Funnel is located on the left side of the
dishwasher tub and can be removed by turning the
¿OOIXQQHOFRXQWHUFORFNZLVHWZLVWORFNGHVLJQ7KHUH
LVDJDVNHWEHWZHHQWKH¿OOIXQQHODQGWXE7KH¿OO
KRVHFRQQHFWVWKHZDWHUYDOYHWRWKH¿OOIXQQHO
VOLTAGE RESISTANCE TEMPERATURE
.95 20066 50°F
1.56 10450 75°F
2.25 5824 100°F
2.91 3411 125°F
3.48 2081 150°F
3.91 1330 175°F
6 - 7 at Main Control
3 - 5 at Flood Switch