You must use with this dryer a flexible metal
connector (listed connector ANSI Z21.24/CSA 6.10).
The length of the connect shall not exceed 3 ft.
Installation Instructions
6
CONNECTING A GAS DRYER (skip for electric dryers) (cont.)
GAS REQUIREMENTS
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
A 1/8” National Pipe Taper thread plugged
tapping, accessible for test gauge connection,
must be installed immediately upstream of the
gas supply connection to the dryer. Contact
your local gas utility should you have questions
on the installation of the plugged tapping.
Supply line is to be 1/2” rigid pipe and equipped
with an accessible shutoff within 6 feet of, and
in the same room with, the dryer.
Use pipe thread compound appropriate for
natural or LP gas or use PTFE tape.
Connect flexible metal connector to dryer and
gas supply.
ADJUSTING FOR ELEVATION
Gas clothes dryers input ratings are based on
sea level operation and need not be adjusted
for operation at or below 2000 ft. elevation. For
operation at elevations above 2000 ft., input
ratings should be reduced at a rate of 4 percent
for each 1000 ft. above sea level.
Installation must conform to local codes and
ordinances or, in their absence, the NATIONAL
FUEL GAS CODE, ANSI Z223.
- Explosion Hazard
WARNING
Use a new CSA International approved flexible
gas supply line. Never reuse old flexible
connectors.
Install an individual manual shut-off valve
within 6ft. of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Securely tighten all gas connections.
If connected to LP gas, have a qualified person
make sure gas pressure DOES NOT exceed 13”
water column.
Examples of a qualified person include: licensed
heating personnel, authorized gas company
personnel, and authorized service personnel.
Failure to do so can result in death, explosion,
or fire.
1-7/8"
3-1/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
The installation must conform with local codes,
or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
or the Natural Gas and Propane Installation
Code, CSA B149.1.
- Fire Hazard
WARNING
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used only
with a natural gas supply. A manufacturer-supplied
conversion kit is required to convert this dryer for
propane gas supply. Use propane gas conversion
kit WE25X217. Conversion must be made by properly
trained and qualified personnel in accordance with
local codes and ordinances.

Other manuals for GE GTD75GCPLDG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE GTD75GCPLDG and is the answer not in the manual?

GE GTD75GCPLDG Specifications

General IconGeneral
Colorgray, diamond gray
Dryer Capactity7.4 cubic feet
Number of Cycles14
Cycle Selectionsantibacterial, bulky items, damp dry, dewrinkle, extended tumble, jeans, mixed load, quick fluff, sanitize, steam dewrinkle, steam refresh, towels/ sheets
Optionsedry, extended tumble, my cycle, delay dry, volume, damp alert
Stackableno
Ventingno
Temperature Settings5
Temperature Selectionshigh, medium, low, extra low, no heat
Temperature Controlno
Delay Startyes
Child Lockno
Cycle Signalyes
Moisture Sensor Optionyes
Steamyes
Smart Homeyes
Weight and Dimensions IconWeight and Dimensions
Depth30 1/2 inches
Height48 inches
Width27 inches

Related product manuals