Installationoftherange.
E
Read these instructions completely and carefully.
3-Wire ConduitInstallation
Remove tim 3 screws flom tim connector block. Insert bme x_dresbet_veen the
connector block terminals and movable nuts. Tighten screws securely. Do not
remove ground strap connection.
WARNING: connector block is approved for Copper wire Connection
only ff aluminum wire is used, see note below.
NOTE: ALUMINUM WIRING
i_ Do not connect aluminum wire to the connector bk)ck.
Use copper building x@e rated fbr the correct amperage and voltage to
make 3 (three) 3" copper jumper x@es. (_onneut wire as per Step 6 or 7
depending on number ofx@es.
i_ Splice copper x@es to aluminum wiring using special connector terminals
designed and UL-approved fbr joining copper to aluminum and follow the
connector manut_tclurer's recolnmended procedure closely.
Wireused,locationandenclosureofspfices,etc,,mustconformto goodwiringpractices
andlocalcodes,
'__. i_ _'_Screw
'_'_Connectorblockterminal
i Flexiblecable
Connectorblock
..<.
Barewiretips