INSTALLATION INSTRUCTIONS
(continued)
PREPARE THE OPENING 
(cent’d)
Flooring lJnder the Range
Your range, like many other household
items, is heavy and can settle into soft
floor coverings such as cushioned vinyl
or carpeting.  When moving the range on this
type of flooring, it should 
be installed on a 1/4
inch thick sheet of plywood (or similar material)
as follows:
When the 
floor covering ends at the front of the
range,  the area that the range will rest on should
be built up with plywood to the same level or
higher
 than the floor covering. This 
will
 allow
the range to be moved for cleaning or servicing.
STEP 2
PREPARE FOR ELECTRICAL CONNECTION
Use only a 3-conductor, or if required a 
4-
conductor range cord set as noted below. These
cord sets are provided with ring type terminals.
The electrical rating of the cord must be 
1251250
volts minimum, 40 amperes.
NOTE: Only a 4-conductor cord 
is
 to be used
when the appliance is installed in a mobile home
or where local codes do not 
permit  grounding
through the neutral.
STEP 3
1. Locate connector block at the  bottom  rear of
range and remove rear wiring cover.
2. Directly below the connector block is a hole
with a knockout ring for accommodating conduit
fittings. Brackets 
provicled
 are used to support
the flexible cord strain relief, 
which must be
securely attached to the cord set.
CTOR
STRAIN R
(PROVIDE
SET NOT
STEP 
4
3-WIRE SYSTEM
Power Cord Installation-Insert screws
through power cord terminals so that the screws
pass through connector block terminals and
engage nuts. Tighten screws securely.
+
SCREW+
POWER CORD
.oNN&L
&
#
 RING TERMINAL
POWER
&
CORD
BLOCK
TERMINAL
@
~
 
-
 
)j:.IABLE
Cable Direct Installation-Clamp bare wires
between the connector block terminals and
movable nuts with screws tightened securely.
1. Copper 
Wiring
CONNECTOR
TERMINAL
CABLE
Connect the neutral or 
~rounded
 wire of the
supply circuit 
to
 the neutral terminal of the
connector block, located in the center. 
The
power leads must be connected to the outside
(brass colored) terminals.
NEUTRAL
TERMINAL
/J 
(&
GROUNDING STRAP
(GROUNDING TO RANGE)
w~ING:
 
coNNJ7~OR
 
BLOCK
 
Is
APPROVED FOR COPPER WIRE
CONNECTION ONLY.
50
—.