Page #77 background imageLoading...
Page #77 background image
4-8 F650 Digital Bay Controller GE Multilin
4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE 4 HUMAN INTERFACES
4
4.1.4 FILE MANAGEMENT
File management with EnerVista 650 Setup software:
4.1.4.1 OFF LINE MODE WITHOUT CONNECTION TO THE RELAY
Figure 4–4: OFF-LINE MODE FILE MANAGEMENT
Run EnerVista F650 Setup
Open a *.650 file
(
“
File>O
p
en
” m e n u
)
M odify protection Settings
and rela
y
confi
g
uration
Is it necessary to
program
additional logic?
Launch the Logic Configuration tool in EnerVista
F650 Setu
p
(
“
Set
p
oint>Lo
g
ic Confi
g
uration
”
)
Create new or m odify the existing logic:
(
“
File>O
en Pro
ect
”
)
Com pile and save logic file (*.pep) and drawing
desi
g
n
(
*.aut
)
in L o
g
ic Confi
g
uration tool
Exit PLC Graphic Editor and save the *.650 file
fro m th e m a in a
pp
lication m enu
Is th e re la y
c o m p le te ly
configured?
Save *.650 settings & configuration file
Store in the com puter the Logic configuration files (*.pep, *.aut, *.lib) as
well as the *.650 for further logic changes.
YES
YES
NO NO

Table of Contents

Other manuals for GE Multilin GEK-113000T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Multilin GEK-113000T and is the answer not in the manual?

GE Multilin GEK-113000T Specifications

General IconGeneral
BrandGE
ModelMultilin GEK-113000T
CategoryController
LanguageEnglish

Related product manuals