The NX-8 can report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a
Zone ID. The zone ID is the zone that generated the alarm. The event code will come from the chart below, and it
will be programmed in the configuration group event code.
Programmed Event Code CONTACT-ID Description
0 122 Silent Panic
1 110 Fire Alarm
2 120 Panic alarm
3 130 Burglary Alarm
4 131 Perimeter Alarm
5 132 Interior Alarm
6 133 24 Hour Burglary
7 134 Entry Alarm
8 135 Day/Night Alarm
9 150 Non Burglary 24 Hour
10 121 Duress Alarm
11 100 Medical Alarm
12 123 Audible Panic Alarm
13 137 Tamper Alarm
14 602 Periodic Test
15 151 Gas Detected
16 158 High Temp
17 154 Water Leakage
18 140 General Alarm
19 140 General Alarm
20 159 Low Temp
21 158 Heat Alarm Restore
22 115 Manual Fire Alarm
NX-8-EUR Installation manual Page 109 02/07/06