[*]-[CHIME] ACTIVATING WALKTEST
1. Enter [*]-[CHIME] The LCD screen will prompt you for a “master code”.
2. Enter [mastercode] The LCD screen will display the “walktest mode”
3. Activate all sensors to test Each activation of a sensor is confirmed with a “ding
dong” sound. The zone texts of the sensors who have
reacted, are displayed one by one on the screen.
4. Enter [mastercode] The walktest mode is left.
Remark:
1. All activations and restore conditions occurred during the walk test, can
be verified by consulting the memory file (see function [*]-[9]-[0])
2. A walk test mode is not possible if any partition is armed or if the
communicator is active.
NX-8-EUR Installation manual Page 25 02/07/06