Segment 5
1 = On: enable lost clock service light
2 =
On: enables Zone Doubling (requires NX-200 Zone Doubling Kit).
3 = On: disables on-board 8 zones
4 = On: will allow two trips on same cross-zone to activate an alarm
5 = On: will not allow zones that are force armed to report bypass
6 = On: enables silent exit option
7 = On: activate “first disarm reporting” - “last arm reporting” for
partitions
8 = On: switch “summer/wintertime” and vice versa
Segment 6
1 = On: enable 2 wire smoke sensors on zone 8
2 = On: Use internal crystal for clock
3 = On: zone activity monitor in hours (not in days)
4 = On: enables first alarm logic
5 = On: enables log protection
6 = On: disables Clean Me report
7 = On: siren output is steady in case of fire alarm
8 = On: valid user code will reset tamper memory
Segment 7
1 = On: dial via GSM when phone line trouble (*)
2 = On: Exit Error limited to Entry/Exit delay 1
3-8 Reserved
(*)Note: This feature is only used when the NX-7002 is enrolled by the panel
and if the NX-7002 is used as backup (GSM voice channel) for the PSTN dialler
of the panel. Also telephone line monitoring needs to be enabled in location
40. Do not use this feature as the only backup feature of the PSTN dialler
but use this in addition with the standard backup options as described in the
NX-7002 manual.
LOCATION 38 - SWINGER SHUTDOWN COUNT
Location 38 contains the number of trips on a zone before that zone will be automatically
bypassed. From 0 to 255. Refer to the feature definitions.
LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data)
Segment 1
1 = On: if keypad sounds for “Telephone Line Cut” when the system is
armed
2 = On: if keypad sounds for “Telephone Line Cut” when disarmed
3 = On: if keypad sounds for an AC power failure
4 = On: if keypad sounds when a low battery is detected
5 = On: if keypad sounds during cross zone trip time
6 = On: if keypad sounds for zone and box tampers
7 = On: if keypad sounds for Emergency keys
8 = Expander trouble
NX-8-EUR Installation manual Page 54 02/07/06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-8-EUR and is the answer not in the manual?

GE NetworX NX-8-EUR Specifications

General IconGeneral
BrandGE
ModelNetworX NX-8-EUR
CategoryControl Panel
LanguageEnglish

Related product manuals