101 71 PARTITION 6, ACCOUNT CODE
10-10-10-10-10-10
PARTITION 6, FEATURE SELECTION
Segment 1 Segment 2 Segment 3
1 Quick Arm 1 LED extinguish enable 1 Open/Close
2 Re-Exit 2 Require user code for bypassing zones 2 Bypass
3 Auto Bypass (interior) 3 Bypass sounder alert 3 Restore
4 Silent Panic 4 AC power/ low battery sounder alert 4 Trouble
5 Audible Panic 5 Enables bypass toggle 5 Tamper
6 Auxiliary 1 6 Enables silent auto arm 6 Cancel
7 Auxiliary 2 7 Enables automatic instant (entry/exit) 7 Recent Closing
8 Multi Keypress Tamper 8 Final set door 8 Exit Error
Segment 4 Segment 5
1 Late to close/early to open 1 Disables auto bypassing of force armable zones
2 Auto arm in stay mode 2 Reserved
3 Enables instant night 3 Reserved
4 Tamper when sensor lost if armed 4 Reserved
5 Enables instant stay toggle 5 Reserved
6 Arming with tamper mem./ comm. failure 6 Reserved
7 Arming with battery trouble 7 Reserved
102 71
8 Keyswitch zone arms in stay mode 8 Reserved
ENTRY/EXIT TIMERS
Segment 1 (Entry Time 1) 0
Segment 2 (Exit Time 1) 0
Segment 3 (Entry Time 2) 0
Segment 4 (Exit Time 2) 0
Reserved 0
103
71
Reserved 0
104 71 PARTITION 7, ACCOUNT CODE
10-10-10-10-10-10
PARTITION 7, FEATURE SELECTION
Segment 1 Segment 2 Segment 3
1 Quick Arm 1 LED extinguish enable 1 Open/Close
2 Re-Exit 2 Require user code for bypassing zones 2 Bypass
3 Auto Bypass (interior) 3 Bypass sounder alert 3 Restore
4 Silent Panic 4 AC power/ low battery sounder alert 4 Trouble
5 Audible Panic 5 Enables bypass toggle 5 Tamper
6 Auxiliary 1 6 Enables silent auto arm 6 Cancel
7 Auxiliary 2 7 Enables automatic instant (entry/exit) 7 Recent Closing
8 Multi Keypress Tamper 8 Final set door 8 Exit Error
Segment 4 Segment 5
1 Late to close/early to open 1 Disables auto bypassing of force armable zones
2 Auto arm in stay mode 2 Reserved
3 Enables instant night 3 Reserved
4 Tamper when sensor lost if armed 4 Reserved
5 Enables instant stay toggle 5 Reserved
6 Arming with tamper mem./ comm. failure 6 Reserved
7 Arming with battery trouble 7 Reserved
105 71
8 Keyswitch zone arms in stay mode 8 Reserved
ENTRY/EXIT TIMERS
Segment 1 (Entry Time 1) 0
Segment 2 (Exit Time 1) 0
Segment 3 (Entry Time 2) 0
Segment 4 (Exit Time 2) 0
Reserved 0
106
72
Reserved 0
NX-8-EUR Installation manual Page 98 02/07/06