53
TCO BASE
HOOD
TCO LOWER
HAOLOGEN
MAG.
TCO
TCO OVEN
CAVITY
TCO UPPER
FRONT HALOGEN
TCO UPPER
REAR HALOGEN
SMART BOARD
RELAY BOARD
CN11
CN1
RY2
CN6 CN4 CN2
DAMPER
DOOR
SENSING
SWITCH
OVEN DOOR MONITOR
INTERLOCK SWITCH (MIDDLE)
CN12
UPPER REAR HALOGEN
RELAY (RY18)
UPPER REAR
HALOGEN TRIAC1
UPPER AIR GAB
RELAY (RY22)
UPPER FRONT
HALOGEN TRIAC2
UPPER FRONT HALOGEN
RELAY (RY19)
LOWER
HALOGEN TRIAC3
LOWER AIR GAB
RELAY (RY21)
LOWER HALOGEN
RELAY (RY20)
UPPER HALOGEN
REAR
U.H.R. TCO
UPPER HALOGEN
FRONT
U.H.F. TCO
LOWER HALOGEN
L.H. TCO
DESCRIPTION CLOSED OPEN
CAVITY 302˚ F 1 Shot
TCO 150˚ C 1 Shot
HALOGEN 293˚ F 140˚ F
TCOs (3) 145˚ C60˚ C
MAGNETRON 302˚ F 140˚ F
(M.G.T.) TCO 150˚ C60˚ C
BASE HOOD 104˚ F 133˚ F
TCO 40˚ C 56˚ F
THERMAL CUT OUTS
(150˚F/1 Shot)
(302˚F/1 Shot)
24.5