GE Multilin T60 Transformer Protection System B-59
APPENDIX B B.4 MEMORY MAPPING
B
B234 ...Repeated for Received Analog 19
B236 ...Repeated for Received Analog 20
B238 ...Repeated for Received Analog 21
B23A ...Repeated for Received Analog 22
B23C ...Repeated for Received Analog 23
B23E ...Repeated for Received Analog 24
B240 ...Repeated for Received Analog 25
B242 ...Repeated for Received Analog 26
B244 ...Repeated for Received Analog 27
B246 ...Repeated for Received Analog 28
B248 ...Repeated for Received Analog 29
B24A ...Repeated for Received Analog 30
B24C ...Repeated for Received Analog 31
B24E ...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290 IEC 61850 Configurable Reports Dataset Items (64
items)
0 to 848 --- 1 F615 0 (None)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B500 Number of Status Indications in GGIO1 8 to 128 --- 8 F001 8
B501 IEC 61850 GGIO1 Indication FlexLogic Operands (128
items)
--- --- 1 F300 0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0 IEC 61850 Configurable GOOSE Function (GoEna) 0 to 1 --- 1 F102 1 (Enabled)
B5A1 IEC 61850 Configurable GOOSE ID --- --- --- F209 “GOOSEOut_x_
B5C2 Configurable GOOSE Destination MAC Address --- --- --- F072 0
B5C5 IEC 61850 Configurable GOOSE VLAN Transmit Priority 0 to 7 --- 1 F001 4
B5C6 IEC 61850 Configurable GOOSE VLAN ID 0 to 4095 --- 1 F001 0
B5C7 IEC 61850 Configurable GOOSE ETYPE APPID 0 to 16383 --- 1 F001 0
B5C8 IEC 61850 Configurable GOOSE ConfRev (Configuration
Revision)
1 to 4294967295 --- 1 F003 1
B5CA IEC 61850 Configurable GOOSE Retransmission Curve 0 to 3 --- 1 F611 3 (Relaxed)
B5CB Configurable GOOSE Dataset Items for Transmission
(64 items)
0 to 1008 --- 1 F616 0 (None)
B60B ...Repeated for Module 2
B676 ...Repeated for Module 3
B6E1 ...Repeated for Module 4
B74C ...Repeated for Module 5
B7B7 ...Repeated for Module 6
B822 ...Repeated for Module 7
B88D ...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900 Configurable GOOSE Dataset Items for Reception
(32 items)
0 to 197 --- 1 F233 0 (None)
B920 ...Repeated for Module 2
B940 ...Repeated for Module 3
B960 ...Repeated for Module 4
B980 ...Repeated for Module 5
B9A0 ...Repeated for Module 6
B9C0 ...Repeated for Module 7
B9E0 ...Repeated for Module 8
BA00 ...Repeated for Module 9
BA20 ...Repeated for Module 10
BA40 ...Repeated for Module 11
BA60 ...Repeated for Module 12
BA80 ...Repeated for Module 13
BAA0 ...Repeated for Module 14
Table B–10: MODBUS MEMORY MAP (Sheet 51 of 65)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT